Abstract
The aim of this study was to evaluate the accuracy of measurements on 3D models obtained with a CBCT and digital scanner, comparing with analog dental plaster casts and therefore determine whether the aforementioned digital models could be implemented in dental education. A total of 120 archived maxillary plaster models were digitized by using two different CBCT techniques, (NewTom, and 3G Planmeca ProMax 3D), and Cerec Omnicam Digital Scanner, Sirona. The mean absolute values among the plaster models, IDS models, and CBCT scans were in the range of 0.12 mm-0.33 mm. The intraclass correlation coefficients for all measured variables showed high reliability. The mean differences for arch width such as inter-canine, inter-premolar and inter-molar as well as mesiodistal width measurements exhibited a mean difference value higher than 0.3 mm (p˂.05). Digital models acquired from plaster casts were reliable for clinical orthodontic practice. Therefore, the use of digital models provides a reliable alternative to plaster models and it can be used in dental education.
License
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Article Type: Research Article
EURASIA J Math Sci Tech Ed, Volume 13, Issue 8, August 2017, 5465-5473
https://doi.org/10.12973/eurasia.2017.00844a
Publication date: 17 Aug 2017
Online publication date: 21 Jun 2017
Article Views: 2747
Article Downloads: 1575
Open Access References How to cite this article